Sea-Bird Electronics SBE 38 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Medição, teste e controlo Sea-Bird Electronics SBE 38. Sea-Bird Electronics SBE 38 User`s manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
SBE 19plus V2
SEACAT Profiler
Conductivity, Temperature, and Pressure Recorder
with RS-232 Interface
Note: NEW ADDRESS
As of January 2010
User’s Manual
Sea-Bird Electronics, Inc.
13431 NE 20
th
Street
Bellevue, Washington 98005 USA Manual Version #006, 04/21/11
Telephone: +1 425-643-9866 Firmware Version 2.3 and later
Fax: +1 425-643-9954 SeatermV2 Version 1.1e and later
[email protected] Seasave V7 Version 7.21d and later
www.seabird.com SBE Data Processing Version 7.21d and later
Vista de página 0
1 2 3 4 5 6 ... 123 124

Resumo do Conteúdo

Página 1 - SEACAT Profiler

SBE 19plus V2 SEACAT Profiler Conductivity, Temperature, and Pressure Recorder with RS-232 Interface Note: NEW ADDRESS As of Ja

Página 2 - Limited Liability Statement

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 10 • SBE 55 ECO Water Sampler - The SBE 55 has built-in capabilities simi

Página 3 - Table of Contents

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 100 Replacing Anti-Foulant Devices (SBE 16plus, SBE 19plus) The S

Página 4

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 101 Sensor Calibration Sea-Bird sensors are calibrated by subjecti

Página 5 - Section 1: Introduction

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 102 Pressure Sensor The SBE 19plus V2 includes a standard strain-g

Página 6 - Unpacking SBE 19plus V2

Manual revision 006 Section 6: Troubleshooting SBE 19plus V2 103 Section 6: Troubleshooting This section reviews common problems in operating the S

Página 7 - System Description

Manual revision 006 Section 6: Troubleshooting SBE 19plus V2 104 Problem 3: Nonsense or Unreasonable Data The symptom of this problem is a data fil

Página 8

Manual revision 006 Glossary SBE 19plus V2 105 Glossary Batteries – Nine alkaline D-cells (Duracell MN1300, LR20) standard. Available with optional

Página 9

Manual revision 006 Glossary SBE 19plus V2 106 Seaterm232 – Win 2000/XP terminal program used with Sea-Bird instruments that communicate via an RS-2

Página 10

Manual revision 006 Appendix I: Functional Description and Circuitry SBE 19plus V2 107 Appendix I: Functional Description and Circuitry Sensors T

Página 11 - Specifications

Manual revision 006 Appendix I: Functional Description and Circuitry SBE 19plus V2 108 Battery Wiring SBE 19plus V2 standard main battery is a seri

Página 12 - Continued from previous page

Manual revision 006 Appendix II: Electronics Disassembly/Reassembly SBE 19plus V2 109 Appendix II: Electronics Disassembly/Reassembly Disassem

Página 13

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 11 Specifications Temperature (°C) Conductivity (S/m) Pressure Measurem

Página 14 - Sample Timing (Moored Mode)

Manual revision 006 Appendix III: Command Summary SBE 19plus V2 110 Appendix III: Command Summary CATEGORY COMMAND DESCRIPTION Status GetCD Get an

Página 15 - Battery Endurance

Manual revision 006 Appendix III: Command Summary SBE 19plus V2 111 CATEGORY COMMAND DESCRIPTION Output Format Setup OutputFormat=x x=0: output r

Página 16

Manual revision 006 Appendix III: Command Summary SBE 19plus V2 112 CATEGORY COMMAND DESCRIPTION Data Upload Stop logging before uploading. GetSam

Página 17 - External Power

Manual revision 006 Appendix III: Command Summary SBE 19plus V2 113 CATEGORY COMMAND DESCRIPTION Calibration Coefficients (F=floating point number

Página 18

Manual revision 006 Appendix IV: AF24173 Anti-Foulant Device SBE 19plus V2 114 Appendix IV: AF24173 Anti-Foulant Device AF24173 Anti-Foulant Devic

Página 19 - Magnetic Reed Switch

Manual revision 006 Appendix IV: AF24173 Anti-Foulant Device SBE 19plus V2 115 AF24173 Anti-Foulant Device FOR USE ONLY IN SEA-BIRD ELECTRONICS’ CO

Página 20 - Vertical Mount

Manual revision 006 Appendix IV: AF24173 Anti-Foulant Device SBE 19plus V2 116 PRECAUTIONARY STATEMENTS HAZARD TO HUMANS AND DOMESTIC ANIMALS DANG

Página 21

Manual revision 006 Appendix IV: AF24173 Anti-Foulant Device SBE 19plus V2 117 STORAGE AND DISPOSAL PESTICIDE STORAGE: Store in original containe

Página 22

Manual revision 006 Appendix V: Replacement Parts SBE 19plus V2 118 Appendix V: Replacement Parts Part Number Part Application Description Quantit

Página 23 - Horizontal Mount

Manual revision 006 Appendix V: Replacement Parts SBE 19plus V2 119 continued from previous page Part Number Part Application Description Quantit

Página 24 - Section 3:

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 12 Continued from previous page Internal Batteries (nominal capacity) Sta

Página 25 - See Seaterm232’s Help files

Manual revision 006 Appendix V: Replacement Parts SBE 19plus V2 120 continued from previous page Part Number Part Application Description Quantit

Página 26

Manual revision 006 Appendix VI: Manual Revision History SBE 19plus V2 121 Appendix VI: Manual Revision History Manual Version Date Description 00

Página 27

Manual revision 006 Appendix VI: Manual Revision History SBE 19plus V2 122 006 04/11 • Firmware 2.3: Add compatibility with WET Labs RS-232 senso

Página 28

Manual revision 006 Index SBE 19plus V2 123 Index . .con file · 50, 51, 64, 78, 80, 89, 101 .xmlcon file · 50, 51, 64, 78, 80, 89, 101 A Aanderaa Op

Página 29

Manual revision 006 Index SBE 19plus V2 124 M Magnetic reed switch · 19 Maintenance · 92 Manual revision history · 121 Memory · 11, 19 Modes · See S

Página 30

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 13 Dimensions and End Cap Connectors Dimensions in millimeters (inches)

Página 31 - Profiling Mode

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 14 Sample Timing (Moored Mode) Sample timing in Moored Mode is dependent

Página 32 - Moored Mode

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 15 Batteries For the main battery, the SBE 19plus V2 uses nine D-cell al

Página 33 - Pump Operation - General

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 16 Moored Mode Examples A 19plus V2 with strain-gauge pressure sensor a

Página 34 - Pump Operation - Moored Mode

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 17 External Power The SBE 19plus V2 can be powered from an external sourc

Página 35

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 18 Supplying Enough Power to SBE 19plus V2 Another consideration in de

Página 36 - Real-Time Setup

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 19 Data Storage The SBE 19plus V2 has a 64 Mbyte FLASH memory. Shown bel

Página 37 - Timeout Description

2 Limited Liability Statement Extreme care should be exercised when using or servicing this equipment. It should be used or serviced only by personn

Página 38 - Command Descriptions

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 20 Configuration Options and Plumbing The standard SBE 19plus V2 include

Página 39

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 21 Shown below is the vertical mount plumbing arrangement of a 19plus V2

Página 40 - Status Commands (continued)

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 22 Shown below is the vertical mount plumbing arrangement of a 19plus V2 c

Página 41

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 23 Horizontal Mount Shown below is the horizontal mount plumbing arrangem

Página 42

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 24 Section 3: Power and Communications Test This section describes soft

Página 43

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 25 Test 1. Double click on SeatermV2.exe. The main screen looks like th

Página 44

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 26 Following is a description of the menus: Menu Description Equivalent

Página 45

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 27 3. If this is the first time Seaterm232 is being used, the Serial Por

Página 46

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 28 Taking a look at the Send Commands window: You can use the Send Com

Página 47

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 29 5. Display 19plus V2 status information by typing DS and pressing th

Página 48

Manual revision 006 Table of Contents SBE 19plus V2 3 Table of Contents Section 1: Introduction ...

Página 49

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 30 Section 4: Deploying and Operating SBE 19plus V2 This sectio

Página 50

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 31 Profiling Mode The SBE 19plus V2 samples data at 4 Hz (one sa

Página 51

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 32 Moored Mode At pre-programmed intervals, the SBE 19plus V2 wa

Página 52

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 33 Pump Operation - General Do not run the pump dry. The pump is

Página 53

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 34 Pump Operation - Moored Mode Pump operation is governed by tw

Página 54

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 35 Moored Mode Pump Setting Recommendations Sea-Bird provides th

Página 55

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 36 Real-Time Setup Baud Rate and Cable Length Without a Sea-Bi

Página 56

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 37 With a Sea-Bird Deck Unit Set the 19plus V2 baud rate to 4800

Página 57

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 38 Command Descriptions This section describes commands and prov

Página 58 - Moored Mode (MM)

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 39 Status Commands GetCD Get and display configuration data, wh

Página 59

Manual revision 006 Table of Contents SBE 19plus V2 4 Section 5: Routine Maintenance and Calibration ... 92 Corrosion Precau

Página 60

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 40 Status Commands (continued) Example: 19plus V2 in Profiling

Página 61

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 41 Status Commands (continued) GetSD Get and display status dat

Página 62

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 42 Status Commands (continued) GetCC Get and display calibratio

Página 63

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 43 Status Commands (continued) GetEC Get and display event coun

Página 64

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 44 Status Commands (continued) GetHD Get and display hardware d

Página 65

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 45 Status Commands (continued) DS Get and display operating stat

Página 66 - Data Output Formats

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 46 Status Commands (continued) Moored Mode (MM) • Firmware v

Página 67

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 47 Status Commands (continued) DCal Get and display calibration

Página 68

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 48 General Setup Commands DateTime=mmddyyyyhhmmss Set real-tim

Página 69

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 49 General Setup Commands (continued) InitLogging Initialize lo

Página 70

Manual revision 006 Section 1: Introduction SBE 19plus V2 5 Section 1: Introduction This section includes a Quick Start procedure, and photos of a

Página 71

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 50 Pressure and Voltage Sensor Setup Commands PType=x Pressur

Página 72

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 51 RS-232 Sensor Setup Commands The SBE 19plus V2 can interface

Página 73

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 52 RS-232 Sensor Setup Commands (continued) Setup for WET Labs S

Página 74

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 53 RS-232 Sensor Setup Commands (continued) Setup for GTD: SBE

Página 75

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 54 RS-232 Sensor Setup Commands (continued) Setup for Aanderaa

Página 76

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 55 Output Format Setup Commands See Data Output Formats after t

Página 77

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 56 Profiling Mode Setup Commands Profiling mode setup commands

Página 78 - Setup for Deployment

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 57 Moored Mode Setup Commands Moored mode setup commands follow

Página 79 - Deployment

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 58 Logging Commands Logging commands direct the SBE 19plus V2 t

Página 80

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 59 Logging Commands (continued) StartNow Start logging now.

Página 81

Manual revision 006 Section 1: Introduction SBE 19plus V2 6 Unpacking SBE 19plus V2 Shown below is a typical SBE 19plus V2 shipment.

Página 82 - Acquiring Real-Time Data

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 60 Data Upload Commands Stop logging before uploading data. If m

Página 83

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 61 Polled Sampling Commands These commands request a single samp

Página 84 - Recovery

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 62 Testing Commands The 19plus V2 takes and outputs 100 samples

Página 85 - Uploading Data

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 63 Testing Commands continued TWetLabs Measure WET Labs RS-232

Página 86

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 64 Calibration Coefficients Commands Calibration coefficients ar

Página 87 - Command/Data Echo Area

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 65 Hardware Configuration Commands The following commands are us

Página 88

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 66 Data Output Formats The SBE 19plus V2 stores data in a compac

Página 89

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 67 OutputFormat=0 (raw frequencies and voltages in Hex) Data is

Página 90

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 68 OutputFormat=1 (engineering units in Hex) Data is output in t

Página 91 - Editing Raw Data File

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 69 OutputFormat=2 (raw frequencies and voltages in decimal) Data

Página 92 - Corrosion Precautions

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 7 Section 2: Description of SBE 19plus V2 This section describes the func

Página 93 - Plumbing Maintenance

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 70 OutputFormat=3 (engineering units in decimal) Data is output

Página 94 - Replacing Alkaline Batteries

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 71 OutputFormat=4 (pressure and scan number in Hex) Data is outp

Página 95

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 72 Uploaded Data (from GetSamples:b,e or DDb,e): <?xml?> &l

Página 96

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 73 Polled Data from SL, SLT, TS, TSS, or TSSOn: If OutputUCSD=Y a

Página 97 - Do not recharge the Ni-Cad

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 74 Optimizing Data Quality for Profiling Applications Our deploy

Página 98 - Barbed caps for cleaning

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 75 When very heavy seas cause severe ship motion, the 19plus V2 d

Página 99 - Pump Maintenance

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 76 Installing Anti-Foul Fittings for Moored Applications The SBE

Página 100 - 8-inch socket wrench;

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 77 4. Intake – A. Remove the two hex head screws attaching the

Página 101 - Sensor Calibration

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 78 Setup for Deployment 1. Install new batteries or ensure the

Página 102 - Pressure Sensor

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 79 Deployment 1. Install a cable or dummy plug for each connec

Página 103 - Section 6: Troubleshooting

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 8 SBE 19plus V2 options / accessories include: • Titanium housing for use

Página 104 - Problem 4: Program Corrupted

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 80 Acquiring Real-Time Data with Seasave Verifying Contents of C

Página 105 - Glossary

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 81 3. The configuration information appears on the Instrument C

Página 106

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 82 Acquiring Real-Time Data Instructions below are for an SBE 19

Página 107 - Sensors

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 83 5. In the Start Real-Time Data Acquisition dialog box, click

Página 108 - Battery Wiring

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 84 Recovery Physical Handling 1. Rinse the instrument and cond

Página 109 - Appendix II:

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 85 Uploading Data 1. Double click on SeatermV2.exe. The main sc

Página 110 - WetLabs=x

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 86 6. Click Upload to upload stored data. Seaterm232 responds as

Página 111

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 87 7. Click the Header Form tab to customize the header: The ent

Página 112

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 88 9. Ensure all data has been uploaded by reviewing and proces

Página 113

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 89 Processing Data Using SBE Data Processing 1. Convert the .he

Página 114 - AF24173 ANTI-FOULANT DEVICE

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 9 • SBE 36 CTD Deck Unit and Power Data Interface Module (PDIM) - These i

Página 115 - AF24173 Anti-Foulant Device

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 90 3. In the Open dialog box, select the .xmlcon or .con file an

Página 116

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 91 Editing Raw Data File Sometimes users want to edit the raw .h

Página 117

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 92 Section 5: Routine Maintenance and Calibration This section re

Página 118

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 93 Plumbing Maintenance For an SBE 19plus V2 with plumbing config

Página 119

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 94 Replacing / Recharging Batteries Leave the batteries in place w

Página 120

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 95 Recharging Optional Nickel Metal Hydride Batteries See the NiMH

Página 121

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 96 4. Reinstall the battery pack in the housing: A. Align the bat

Página 122

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 97 Recharging Optional Nickel-Cadmium Batteries The Ni-Cad battery

Página 123

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 98 Conductivity Cell Maintenance The SBE 19plus V2’s conductivity

Página 124

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 99 Pressure Sensor Maintenance Pressure sensor maintenance varies,

Comentários a estes Manuais