Sea-Bird Electronics SBE 38 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Medição, teste e controlo Sea-Bird Electronics SBE 38. Sea-Bird Electronics SBE 38 User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Sea-Bird Electronics, Inc.
13431 NE 20th Street
Bellevue, Washington 98005 USA
Tel
: 425/643-9866
Fax:425/643-9954
SBE 45 MicroTSG
THERMOSALINOGRAPH
Conductivity and Temperature Monitor
with RS-232 Interface
Serial Number: 4565557-0383
User Manual, Version 015
Vista de página 0
1 2 3 4 5 6 ... 103 104

Resumo do Conteúdo

Página 1 - THERMOSALINOGRAPH

Sea-Bird Electronics, Inc. 13431 NE 20th StreetBellevue, Washington 98005 USA Tel: 425/643-9866 Fax:425/643-9954 SBE 45 MicroTSGTHERMOSALINOGRAP

Página 2

2 Limited Liability Statement Extreme care should be exercised when using or servicing this equipment. It should be used or serviced only by personn

Página 3 - TABLE OF CONTENTS

WARRANTY POLICY 2010 PRODUCT WARRANTY 5-YEAR LIMITED WARRANTY (NEW PRODUCTS) For a period of five years after the date of original shipment from

Página 4

WARRANTY ADMINISTRATION POLICY Sea-Bird Electronics, Inc. and its authorized representatives or resellers provide warranty support only to the orig

Página 5

SOFTWARE WARRANTY SOFTWARE LICENSE AGREEMENT By downloading or installing any of our software, you expressly agree to the following: Sea-Bird&apo

Página 6

Sea-Bird Service Request Form To return instruments for calibration or other service, please provide the information below, so we can serve you bette

Página 7

PAYMENT/BILLING INFORMATION [ ] Credit Card (Sea-Bird accepts payment by VISA, Master Card, or American Express) Name on Card: Please call Ch

Página 8 - (Thermosalinograph)

Table of Contents SBE 45 3Table of Contents Section 1: Introduction ... 5 Ab

Página 9

Table of Contents SBE 45 4Appendix I: Functional Description... 43 Sensors...

Página 10 - Limited Liability Statement

Section 1: Introduction SBE 45 5Section 1: Introduction This section includes a Quick Start procedure, and photos of a standard SBE 45 MicroTSG

Página 11 - Table of Contents

Section 1: Introduction SBE 45 6Unpacking MicroTSG Shown below is a typical MicroTSG shipment.

Página 12 - Table of Contents SBE 45

Section 2: Description of MicroTSG SBE 45 7Section 2: Description of MicroTSG This section describes the functions and features of the MicroTSG,

Página 13 - Section 1: Introduction

Section 2: Description of MicroTSG SBE 45 8An optional AC- or DC-powered 90402 - SBE 45 Power, Navigation, and Remote Temperature Interface Box pr

Página 14 - Unpacking MicroTSG

Section 2: Description of MicroTSG SBE 45 9Specifications Temperature (°C) 1 Conductivity (S/m) Salinity (PSU), typical Measurement Range -5

Página 15 - System Description

Section 2: Description of MicroTSG SBE 45 10Dimensions and Connector Dimensions in millimeters (inches) Ground pin = Computer data

Página 16

Section 2: Description of MicroTSG SBE 45 11Sample Timing The time to acquire the temperature and conductivity varies, depending on the mode of o

Página 17 - Specifications

This page intentionally left blank.

Página 18 - Dimensions and Connector

Section 2: Description of MicroTSG SBE 45 12Baud Rate, Cable Length, Power, and Data Transmission Rate Baud Rate, Cable Length, and Data Transmi

Página 19 - Sample Timing

Section 2: Description of MicroTSG SBE 45 13Power and Cable Length There are two issues to consider: • Limiting the IR loss to 1 volt; higher I

Página 20

Section 2: Description of MicroTSG SBE 45 14Remote Temperature Sensor (optional) The optional 90402 – SBE 45 Power, Navigation, and Remote Tempe

Página 21 - Power and Cable Length

Section 3: Installing System SBE 45 15Section 3: Installing System This section provides information on: • Software installation • System schem

Página 22

Section 3: Installing System SBE 45 16System Schematic and Installation Guidelines MicroTSG with Optional PN 90402 Interface Box, SBE 38 Remot

Página 23 - Section 3: Installing System

Section 3: Installing System SBE 45 17Sea-Bird does not provide detailed installation instructions for the MicroTSG, given the unique nature of ev

Página 24

Section 3: Installing System SBE 45 18Power-Up Jumper Check The MicroTSG’s Printed Circuit Board (PCB) has a jumper that controls how the MicroT

Página 25 - MicroTSG data stream

Section 3: Installing System SBE 45 19Installing MicroTSG 1. New MicroTSGs are shipped with an AF24173 Anti-Foulant Device pre-installed. Verify

Página 26 - Power-Up Jumper Check

Section 4: Setting Up MicroTSG SBE 45 20Section 4: Setting Up MicroTSG This section provides information on: • MicroTSG setup • Sampling modes

Página 27 - Installing MicroTSG

Section 4: Setting Up MicroTSG SBE 45 21 2. The main screen looks like this: • Menus – Contains tasks and frequently executed instrument comma

Página 28 - See SEATERM’s Help files

SEA-BIRD ELECTRONICS, INC. 13431 NE 20th St.Bellevue, Washington 98005 USAPhone: (425) 643 9866Fax: (425) 643 9954Email: [email protected] 45 M

Página 29 - Toolbar

Section 4: Setting Up MicroTSG SBE 45 22Following are the Toolbar buttons applicable to the MicroTSG: Toolbar Buttons Description Equivalent Comm

Página 30

Section 4: Setting Up MicroTSG SBE 45 23 4. In the Communications menu, select Options / Cycle baud when connecting. 5. Click Connect on the T

Página 31

Section 4: Setting Up MicroTSG SBE 45 24Sampling Modes The MicroTSG has three basic sampling modes for obtaining data: Polled Sampling, Autonomou

Página 32 - Sampling Modes

Section 4: Setting Up MicroTSG SBE 45 25Autonomous Sampling The MicroTSG samples data at pre-programmed intervals, defined by Interval=, and send

Página 33 - Autonomous Sampling

Section 4: Setting Up MicroTSG SBE 45 26Serial Line Synchronization (Serial Line Sync) In Serial Line Sync Mode, a simple pulse (a single charact

Página 34 - Timeout Description

Section 4: Setting Up MicroTSG SBE 45 27Command Descriptions This section describes commands and provides sample outputs. See Appendix III: Comma

Página 35 - Command Descriptions

Section 4: Setting Up MicroTSG SBE 45 28Setup Commands Baud=x x= baud rate (1200, 2400, 4800, 9600, 19200, or 38400). Default 4800. Outp

Página 36

Section 4: Setting Up MicroTSG SBE 45 29Operating Commands Operating commands configure the MicroTSG’s response upon waking up, and direct the Mi

Página 37

Section 4: Setting Up MicroTSG SBE 45 30Polled Sampling Commands These commands are used by an external controller to request a sample from the M

Página 38

Section 4: Setting Up MicroTSG SBE 45 31Calibration Coefficients Command DC Display calibration coefficients. Equivalent to Coefficients on Tool

Página 39

Manual Generation Date: 26 August 20111

Página 40 - Data Output Format

Section 4: Setting Up MicroTSG SBE 45 32Data Output Format Each scan ends with a carriage return <CR> and line feed <LF>. Leading zer

Página 41

Section 4: Setting Up MicroTSG SBE 45 33Setting Up Configuration (.xmlcon or .con) File Seasave and SBE Data Processing, our real-time data acqu

Página 42 - Section 5: Operating System

Section 5: Operating System SBE 45 34Section 5: Operating System This section covers acquiring real-time data with Seasave, and processing data w

Página 43

Section 5: Operating System SBE 45 354. In the RealTime Data menu, select Start Acquisition. The dialog box looks like this: 5. In the Start R

Página 44 - Processing Data

Section 5: Operating System SBE 45 36Processing Data Process the data in SBE Data Processing. 1. Convert the .hex data file created by Seasave

Página 45 - Cleaning and Storage

Section 6: Routine Maintenance and Calibration SBE 45 37Section 6: Routine Maintenance and Calibration This section reviews corrosion precaution

Página 46

Section 6: Routine Maintenance and Calibration SBE 45 38Step 3: Flush Inside of Conductivity Cell A. Remove the external plumbing connecting the

Página 47

Section 6: Routine Maintenance and Calibration SBE 45 39Replacing Anti-Foulant Device (SBE 45) The MicroTSG has an anti-foulant device cup inside

Página 48 - Sensor Calibration

Section 6: Routine Maintenance and Calibration SBE 45 40Sensor Calibration Sea-Bird sensors are calibrated by subjecting them to known physical c

Página 49 - Section 7: Troubleshooting

Section 7: Troubleshooting SBE 45 41Section 7: Troubleshooting This section reviews common problems in operating the MicroTSG, and provides the m

Página 50 - Glossary

L I M I T E D L I A B I L I T Y S T A T E M E N T Extreme care should be exercised when using or servicing this equipment. It should be used orse

Página 51 - Sensor Interface

Glossary SBE 45 42Glossary Fouling – Biological growth in the conductivity cell during deployment. PN 90402 - SBE 45 Power, Navigation, and Remote

Página 52 - Appendix II:

Appendix I: Functional Description SBE 45 43Appendix I: Functional Description Sensors The MicroTSG embodies the same sensor elements (3-electro

Página 53

Appendix II: Electronics Disassembly/Reassembly SBE 45 44Appendix II: Electronics Disassembly/Reassembly Do not disassemble the MicroTSG electro

Página 54

Appendix III: Command Summary SBE 45 45Appendix III: Command Summary CATEGORY COMMAND DESCRIPTION Status DS Display status. Baud=x x= baud rate (

Página 55

Appendix III: Command Summary SBE 45 46 CATEGORY COMMAND DESCRIPTION TS Take sample, hold converted data in RAM, output converted data TSR Take sa

Página 56 - AF24173 Anti-Foulant Device

Appendix IV: AF24173 Anti-Foulant Device SBE 45 47Appendix IV: AF24173 Anti-Foulant Device AF24173 Anti-Foulant Devices supplied for user replac

Página 57

Appendix IV: AF24173 Anti-Foulant Device SBE 45 48AF24173 Anti-Foulant Device FOR USE ONLY IN SEA-BIRD ELECTRONICS’ CONDUCTIVITY SENSORS TO CONTR

Página 58

Appendix IV: AF24173 Anti-Foulant Device SBE 45 49PRECAUTIONARY STATEMENTS HAZARD TO HUMANS AND DOMESTIC ANIMALS DANGER Corrosive - Causes irre

Página 59

Appendix IV: AF24173 Anti-Foulant Device SBE 45 50 STORAGE AND DISPOSAL PESTICIDE STORAGE: Store in original container in a cool, dry place. Pre

Página 60

Appendix V: Replacement Parts SBE 45 51Appendix V: Replacement Parts Part NumberPart Application Description Quantity in MicroTSG30541 3/8"

Página 61 - Index SBE 45

This page intentionally left blank.3

Página 62 - Deployment

Index SBE 45 52Index . .con file · 33 .xmlcon file · 33 A Anti-Foulant Device · 47 removal before shipping to Sea-Bird · 40 replacing · 39 B Baud ra

Página 63

Index SBE 45 53S Sample timing · 11 Sampling modes · 24 SBE 38 remote temperature sensor · 14, 16 SBE Data Processing · 8, 15, 33, 36 Schematic · 16

Página 64 - MicroTSG (Thermosalinograph)

Reference Sheet Version #007, 06-11-08; Firmware Version 1.1b 1SBE 45 MicroTSG (RS-232) Reference Sheet (see SBE 45 MicroTSG User’s Manual for comple

Página 65

Reference Sheet Version #007, 06-11-08; Firmware Version 1.1b 2Command Instructions and List • Input commands in upper or lower case letters and reg

Página 66 - CALIBRATION SHEETS

MicroTSG (Thermosalinograph)SBE 45Sea-Bird Electronics, Inc.13431 NE 20th Street, Bellevue, Washington 98005 USAWebsite: http://www.seabird.comE-mai

Página 67 - 24-Aug-11 -0.00

MicroTSG (Thermosalinograph)SBE 45Sea-Bird Electronics, Inc.13431 NE 20th Street, Bellevue, Washington 98005 USAWebsite: http://www.seabird.comE-mai

Página 68 - 24-Aug-11 1.0000000

CALIBRATION SHEETSSBE 45 Temperature Calibration - S/N 0383...

Página 69 - APPLICATION NOTES

SEA-BIRD ELECTRONICS, INC.13431 NE 20th Street, Bellevue, Washington, 98005-2010 USAPhone: (425) 643 - 9866 Fax (425) 643 - 9954 Email: seabird@seabir

Página 70 - General Discussion

SEA-BIRD ELECTRONICS, INC.13431 NE 20th Street, Bellevue, Washington, 98005-2010 USAPhone: (425) 643 - 9866 Fax (425) 643 - 9954 Email: seabird@seabir

Página 71 - Active Use (after each cast)

APPLICATION NOTESAppnote 2DConductivity...

Página 73 - For 100 cc of solution:

1 APPLICATION NOTE NO. 2D Revised October 2010 Instructions for Care and Cleaning of Conductivity Cells This application note presents new re

Página 74

2Rinsing, Cleaning, and Storage Procedures Note: See Cleaning Materials below for discussion of appropriate sources / concentrations of water, Trito

Página 75

3Cleaning Materials Water De-ionized (DI) water, commercially distilled water, or fresh, clean, tap water is recommended for rinsing, cleaning, an

Página 76

4Acid In rare instances, acid cleaning is required for mineral contamination of the conductivity cell. Sea-Bird recommends that you return the equip

Página 77 - (recommended)

5Application Note Revision History Date Description January 1998 Initial release. October 2002 Remove reference to part number for the small anti-

Página 78

APPLICATION NOTE NO. 6 Revised August 2004 DETERMINATION OF SOUND VELOCITY FROM CTD DATA Use of CTD measurement for determination of sound vel

Página 79

We draw the following conclusions from the research papers listed above: 1) Investigators using specialized equipment under scrupulously controlled

Página 80

APPLICATION NOTE NO. 10 Revised March 2008 COMPRESSIBILITY COMPENSATION OF SEA-BIRD CONDUCTIVITY SENSORS Sea-Bird conductivity sensors provide

Página 81

DISCUSSION OF PRESSURE CORRECTION Conductivity cells do not measure the specific conductance (the desired property), but rather the conductance of a

Página 82

APPLICATION NOTE NO. 14 January 1989 1978 PRACTICAL SALINITY SCALE Should you not be already familiar with it, we would like to call yo

Página 83

Instrument Configuration: Serial Number 37SI64195-8524 Pressure Sensor None Firmware Version 3.0j Memory 8192Kb Interface Type RS-232

Página 85

1 APPLICATION NOTE NO. 31 Revised February 2010 Computing Temperature and Conductivity Slope and Offset Correction Coefficients from Laboratory

Página 86

2 To correct conductivity data taken between pre- and post-cruise calibrations: islope = 1.0 + (b / n) [(1 / postslope) - 1.0] where islope = int

Página 87

3 Example Three salinity bottles are taken during a CTD profile; assume for this discussion that shipboard analysis of the bottle salinities is perfec

Página 88 - ITS-90 TEMPERATURE SCALE

4 Temperature Sensors The temperature sensor slope and offset entries in the configuration (.con or .xmlcon) file in SEASOFT permit the user to make

Página 89

5 Correcting for Temperature Drift Based on Pre- and Post-Cruise Laboratory Calibrations Suppose a temperature sensor is calibrated (pre-cruise), the

Página 90 - Revised March 2008

6 Appendix I: Example Conductivity Calibration Sheet 83

Página 91

7 Appendix II: Example Temperature Calibration Sheet 84

Página 92 -

1 APPLICATION NOTE NO. 42 Revised February 2010 ITS-90 TEMPERATURE SCALE Beginning in January 1995, Sea-Bird's temperature metrology laborat

Página 93

1 APPLICATION NOTE NO. 68 Revised June 2009 Using USB Ports to Communicate with Sea-Bird Instruments Most Sea-Bird instruments use the RS-232

Página 94

SBE 45 MicroTSG (Thermosalinograph) Conductivity and Temperature Monitor with RS-232 Interface Note: NEW ADDRESS as

Página 95

1 APPLICATION NOTE NO. 71 Revised March 2008 Desiccant Use and Regeneration (drying) This application note applies to all Sea-Bird instruments in

Página 96 - DRAWINGS

2 Regeneration (drying) of Desiccant Replacement desiccant bags are available from Sea-Bird: • PN 60039 is a metal can containing 25 1-gram desiccan

Página 97

ISO 9002 CERTIFIED Sud-Chemie Performance Packaging 101 Christine Dr. Belen, New Mexico 87002 Phone: (505) 864-6691 Fax: (505) 864

Página 98

ISO 9002 CERTIFIED Sud-Chemie Performance Packaging 101 Christine Dr. Belen, New Mexico 87002 Phone: (505) 864-6691 Fax: (505) 864

Página 99

ISO 9002 CERTIFIED Sud-Chemie Performance Packaging 101 Christine Dr. Belen, New Mexico 87002 Phone: (505) 864-6691 Fax: (505) 864

Página 100 - WARRANTY POLICY 2010

ISO 9002 CERTIFIED Sud-Chemie Performance Packaging 101 Christine Dr. Belen, New Mexico 87002 Phone: (505) 864-6691 Fax: (505) 864

Página 101

DRAWINGSDwg 50179SBE 45 External I/O Wiring, RS-232...

Comentários a estes Manuais

Sem comentários